MRT2000 Digital х-γ Radiation Dosimeter
Mitech
Dose rate:0.01~200.00Sv/h ,Dose:0~10Sv
≥350CPS/ μSv/h
1.2Kg
42*23*15cm
45*28*11.5cm
2kg
Product
- Overview
- Graphic
- Technical
- Configuration
- Related
Product
- Overview
- Graphic
- Technical
- Configuration
- Related
-
Product Overview
MRT2000 X -γ Radiation Detector chooses high sensitive scintillation crystal as detector, quick reaction ,which is the special instrument of the radiation dose rate used to monitor X-ray and gamma rays of various radioactive workplace.It adopts full color LCD display, and the backlight can be adjusted.Equipped with the function of super-threshold alarm,and its alarm threshold can be setted within the measurement range.The function of timing recording measurement result makes it possible to check the alarm record.Compared with the same kind of instrument, the instrument has wider dose rate measurement range and good characteristic of energy response ,which is widely used in all kinds of applications needed radiation environment and radiation protection test,such as environmental protection, metallurgy, oil,chemical and so on .It’s the first choice for X -γ Radiation Detector .
Function & application
MRT2000 X -γRadiation Detector is widely used in all kinds of applications needed radiation environment and radiation protection test,such as environmental protection, metallurgy, oil,chemical and so on
Working Principle
Using sodium iodide and photomultiplier tube principle
Working Conditions
Working temperature:- 10℃~+50℃;Instrument Features
NaI scintillating crystal detector with high-sensitivity and fast response
Detecting time between 1~600 second
International standard unit of uGy/h (environment) and uSv/h (protection)
Large-size lattice LCD display with backlight function
Real-time show battery capacity and alarm against low battery
Light touch control panel
Dose rate alarm with double alarm threshold
Real-time clock with backup battery
Data storage and check
Programmable sound, light and vibration alarmOperating Method and Attentions
Instrument Maintenance
High pressure inside the instrument,forbidden to remove!
When not in use, turn off the instrument and remove the batteries to avoid over discharge of the batteries, result in instrument damage.
-
-
Detector Dia30x25mm, NaI scintillating crystal Measurement range Dose rate:0.01~200.00Sv/h ,Dose:0~10Sv Accuracy ≥350CPS/ μSv/h Energy Response 48Kev~3Mev≤±30% (based on 137Cs) Relative Deviation ≤±10% Power two standard No.1 battery Dimensions 420*180*88(mm) Weight 1.30Kg -
-